Low sorbing. PVC free tubing in the fluid path designed to minimize absorption of drugs (for example nitroglycerin) into the matrix of tubing materials. Also prevents leaching (has inert internal surface).
· Sorbing Tubing Low Sorbing Short Set (Low Sorb Short Chemo Set for Alaris Pump Module set Low Roller Clamp(s) 2-piece Male Luer Lock. Not Made with DEHP. 20 Drop L 47 in L 120 cm PV 15 mL Fluid Path Sterile Oncology Areas ECCC Battle 7 Acute 8 West Stem Cell Hope . Page 3 of 6 72923 97242 97258 Tubing Low
Alaris™ Pump Module set Low Sorbing Roller Clamp(s) 2-piece Male Luer Lock. Not Made with DEHP. 20 Drop L 113 in L 286 cm PV 23 mL Fluid Path Sterile
· Tubing Set 2.5 ml 19” / 48cm 11 Liters/ hour3 Y-Site Tubing 3.2ml/1.6ml 9” / 21cm 13 Liters/ hour3 LL-1DC 0.10ml LL-1C 0.10ml 1. Measured at 3’ height difference, fully assembled with IV bag and secondary tubing 2. Measured at 3’ height difference with Female Connector Luer Lock Adaptor fully assembled at one end of a secondary tubing
Low sorbing. PVC free tubing in the fluid path designed to minimize absorption of drugs (for example nitroglycerin) into the matrix of tubing materials. Also prevents leaching (has inert internal surface). 0.2 Micron Filter. Removes particulate matter larger than 0.2 microns and virtually all fungi and bacteria. Often used as final filter for
15 µm Drip Chamber Filter. 1 Pinch Clamp (s) 1 Roller Clamp (s) Alaris™ Safety Clamp. Pump Segment. 1 Male Luer (s) Low Sorbing. Natural rubber latex is not part of the material formulation. DEHP is not part of the material formulation.
1 Pinch Clamp (s) Pressure Sensor Disc. 1 Female Luer (s) 1 Male Luer (s) Low Sorbing. Polyethylene lined PVC. Natural rubber latex is not part of the material formulation. DEHP is not part of the material formulation. Quantity 100.
· Tubing material Units / Box PE-Lined PVC PB-G40701 10 Fix PE-lined PVCLow sorbing 40 PB-G40702 20 Fix PE-lined PVCLow sorbing 40 PB-G40703 30 Fix PE-lined PVCLow sorbing 40 PB-G40705 50 Fix PE-lined PVCLow sorbing 40 PB-G40707 70 Fix PE-lined PVCLow sorbing 40 PB-G40710 100 Fix PE-lined PVCLow sorbing 40
71 rows · Alaris™ Pump Module Set 150mL Burette (SmartSite™) Smallbore Tubing Segments Low
103″ V/NV 20 dp low sorbing tubing set w/ .2 micron filter IVAC SIGNATURE 7100/7200 72943 100″ V/NV microbore tubing set w/ no injection site IVAC SIGNATURE 7100/7200 72953 108″ V/NV 20 dp low sorbing tubing set w/ no injection port IVAC SIGNATURE 7100/7200 72963 100″ V/NV 60 dp minidrip set w/ 2 injection sites IVAC
Low-Sorbing Tubing Filter 0.2 micron SmartSite™ needle-free valve 1 for IVP Not made with DEHP Case of 20 BD/Carefusion# Additional 8100 IV Pump Administration Sets are availableContact a DiaMedical account manager for more information
· Administer through a non-PVC (low-sorbing) infusion set. DOXORUBICIN Preparation • Use doxorubicin injection 2 mg/mL or doxorubicin powder for reconstitution. • Dilute the powder to a concentration of 2 mg/mL with NS. • Intravenous Dispense in Syringe for IV injection. 50 mL to 100 mL NS or D5W for infusion. • Bladder irrigation
· Specializes in ICU,CCU, MICU, SICU, CVICU, CTSICU,ER. Jul 31, 2009. No stopcock but our policy is to change tubing q 12. We run D5 as a backup with the diprivan, diprivan placed on a seperate pump, placed at the y port. No stopcock would be needed as we can simply titrate the diprivan on it's own pump.
· This has been studied using regular 10% lipids and Propofol in a 10% lipid emulsion. The stopcocks cracked with both so it's clearly the lipids that are the problem. The stopcocks that are packaged with the Propofol aren't required for infusion but if you need to use a stopcock then that's the one you have to use.
· Additional Details Alaris Pump Infusion Set . Alaris Pump Module Set Low Sorbing (PE Lined) Back Check Valve 0.2 Micron Filter (1.72 sq. in Low Protein Binding) Roller, Pinch Clamp(s) 2 SmartSite Ysite(s) 6", 89" (1 above pumping segment and 1 below) from 2-piece Male Luer Lock.
A secondary tubing administration set is used for secondary IV medication. Figure 8.4 IV Primary and secondary tubing set up. IV solution bags should have the date, time, and initials of the health care provider marked on them to be valid. Add-on devices (e.g., extension tubing or dead-enders) should be changed every 96 hours, if contaminated
· secondary tubing for chemotherapy administration to a primary setup that employed low-sorbing tubing and placed a PhaSeal™ (Becton, Dickinson and Company) CSTD at the connection to the patient’s central line. In the following months,
· Specializes in ICU,CCU, MICU, SICU, CVICU, CTSICU,ER. Jul 31, 2009. No stopcock but our policy is to change tubing q 12. We run D5 as a backup with the diprivan, diprivan placed on a seperate pump, placed at the y port. No stopcock would be needed as we can simply titrate the diprivan on it's own pump.
A secondary tubing administration set is used for secondary IV medication. Figure 8.4 IV Primary and secondary tubing set up. IV solution bags should have the date, time, and initials of the health care provider marked on them to be valid. Add-on devices (e.g., extension tubing or dead-enders) should be changed every 96 hours, if contaminated
· In Stock! Ships Today! $199.00 box of 20BD # BD Alaris Pump Infusion Set 0.2 Micron Filter Low Sorbing Tubing (PE Lined) Back Check Valve, Two SmartSite Y-Sites
B-D20350ETH. Low Sorbing IV Set with 0.2 Micron Filter SmartSite Needle-Free Valve and Closed Male Luer, 19". 1 EA. Stock Allocated QTY / Remaining QTY / Allocation Reset Date IME20350ET. Low Sorbing IV Extension Set with 0.2 Micron Filter, 1 SmartSite Needle-Free Valve 6" from Texium Closed Male Luer, 20", 6 mL Priming Volume, Non-DEHP
· Low sorbing PVC free tubing in the fluid path designed to minimize absorption of drugs (for example nitroglycerin) into the matrix of tubing materials. Also prevents leaching (has inert internal surface). Microbore Tubing with smaller internal diameter ≤ 0.04” to minimize the contained volume. Often used in Pediatric and
Carefusion is recalling the smartsite low sorbing infusion set with texium closed male luer because it is not assembled with low-sorbing tubing. Action The firm, CareFusion, sent an "URGENT Medical Device Recall Notification" letter dated November 8, 2013 to all customers who purchased the SmartSite Low Sorbing Infusion Set with Texium Closed
Details. Manufacturer Number . Packaging 100 each/case. Feature / Property Standard bore Tubing, Low Sorbing, 0.2Micron Filter, Pinch Clamp, SmartSite Needle-Free Valve, Two Piece Male Luer Lock, Sterile Fluid Path, 0. Invoice Description SET EXTEN 0.2 MIC LOW SORB TBG 1 NF VLV 2PC MALE LL 100EA/CA.
Thermo Scientific Pierce Low Protein Binding Microcentrifuge Tubes (1.5 mL) help minimize protein sample loss during sample manipulation and are ideal in applications where processing steps are extensive. Durableable to tolerate centrifuge speeds up to
Infusion Pumps & Tubing IV Catheters, PICC, Securement IV Extension Sets Kits Mopping & Hood Cleaning Systems Needleless Valves & Extension Sets Pharmacy Accessories Rate Controlled & Gravity IV Tubing Syringe CapsRegular & Tamper Evident
· Nitroglycerin (polyethylene-lined tubing) ULTRABLOCK™ UV light sensitive protected Contact a Representative. Please take a minute to complete the request form or call to contact a B. Braun representative. Thank you. more. Products Description Product Code
Alaris Pump Module set Low Sorbing 0.2 Micron Filter (1.72 sq. in Low Protein Binding) Roller, Pinch Clamp (s) 1 SmartSite needle-free valve (s) 6" (below pumping segment) from 2-piece Male Luer Lock. Not Made with DEHP. 20 Drop L 115 in L 291 cm PV 26 mL Fluid Path Sterile.
A primary IV low-sorbing, polyethylene-lined tubing set (reference , Carefusion, Mississauga, Ontario [tubing set manufactured in Mexico]) was then connected to each bag. The tubing was 286 cm long, with a priming volume of 23 mL. The infusion sets were primed with insulin solution, so that all air bubbles were eliminated.
Alaris Nonvented Infusion Set with Needle-Free Bag Access Port, Low Sorbing Tubing Segment, Check Valve, 3 Needle-Free Valves 95" and 75" and 6" from 2-Piece Male
Low Sorbing Set Alaris® 20 Drops / mL Drip Rate 115 Inch Tubing 1 Port. Bonded Connector 1.72 Sq. Inch Low Protein Binding Valve(s) 6 Inch Above Bonded Texium Closed Male Luer From Texium Close
Microbore Low Sorbing Tubing, 1.3mL Priming Volume, L60" Administration sets for use with the Alaris syringe module.
· We are using both methods. Secondary for most infusions and primary (or dedicated line) for chemo drugs that required low sorbing tubing or other requirement. Both systems are fine. The closed system also available in both primary and secondary set. Diana